K-type fryer thermostat with knob, 200–400 °F, 5/16 in × 8-1/16 in nickel bulb, 96 in capillary. Used across Vulcan VF/VMF series and a range of Garland fryers.
Currently listed as a genuine OEM replacement part on PartsTown.
Source: public distributor listing, checked 2026-10-19. Availability changes; re-check before ordering.
OEM (quote only).
Source: public product listing at a major US parts retailer, checked 2026-10-20. This is a market observation for reference only — it is not an offer, a quotation, or a commitment to supply at any price.
This item is listed under the following part numbers across manufacturer documentation and distributor catalogs:
00-414880-00001414880-00001414880-1114880-124145-20VH414880-1VH114880-1VH24145-20| Type | K |
|---|---|
| Temperature range | 200–400 °F |
| Bulb | 5/16 in × 8-1/16 in, nickel |
| Capillary length | 96 in |
| Mount | 1 |
| Dial options | #22-1353 (indicator knob, 1-1/4 in dia.), #22-1191, #22-1006 |
These are the points that most often cause a wrong order on this specific part number. They are not generic advice.
Compiled from manufacturer catalog strings and distributor listings. Verify against your own equipment's parts manual before ordering. This is not an offer or a quotation.
Distributor listing only. The K thermostat is the 5/16 in bulb unit with the long 96 in capillary, which is the number to match before substituting an RX or KX.
| Source | Wording (verbatim) | What it is | Link |
|---|---|---|---|
| SharpTek Supply listing (distributor wording, not OEM) | “Thermostatk, 5/16 X 8-1/16, 96 for Hobart - Part# 00-414880-00001” | Bulb diameter, bulb length and capillary length in the title. | sharpteksupply.com |
Controls fryer oil temperature where a long (96 in) capillary run is required — this is the longest capillary variant in this family, useful when the control panel is distant from the fry tank.
A vapour-charged sensing bulb and capillary drive a diaphragm; the dial biases a set of contacts against it. There is no electronics inside. When a unit like this fails it fails in one of four ways: the contacts weld closed (heat keeps rising), the contacts open and stay open (no heat at all), the charge is lost through a cracked bulb or a kinked capillary (the unit behaves as if the oil is always cold), or the calibration drifts so the dial no longer matches the oil temperature. Only the last one still 'works' — which is why it is the one that quietly overcooks oil or trips the hi-limit.
| Symptom | This part? | Check first |
|---|---|---|
| Oil keeps climbing past the dial setting until the hi-limit trips | Yes — contacts welded closed | Hi-limit continuity first; whether the burner stays lit with the dial turned to OFF |
| No heat, pilot or ignition sequence fine, dial turned up | Possible — contacts open, or charge lost | Gas-valve operator signal, hi-limit continuity, ignition sequence |
| Dial setting and oil temperature disagree by more than a few degrees | Possible — drift, or a fouled / mis-seated bulb | Bulb coating and immersion depth; cross-check the oil with a separate thermometer |
| Dial turns with no resistance, or no click at either end of the range | Possible — stripped shaft or detached capillary | Capillary routing at the stuffing box (kinks, crushed sections) |
Vulcan fryers (VF1, VF1D, VF90, VFD90, VMF1, VMF1D and the VF/VMF/VTMF families) and Garland fryers including 36ES series, 36FS-21, 680 series, 780 series, E22 and E24.
96 inches — the longest variant in this thermostat family.
Yes — 414880-1 is the same part number written without the 00- prefix.
Capillary, millivolt and high-limit thermostats in these part families are produced in volume in China. Public supplier directories list manufacturers concentrated in specific industrial clusters: Zhongshan (Guangdong) for capillary, millivolt and deep-fryer thermostats; Wenzhou (Zhejiang) for capillary, gas, immersion and mechanical thermostats with OEM/ODM capability; and Jinan (Shandong) for gas-valve and thermostatic gas-control components. When sourcing these parts from China, verify: dimensional drawings, sensing-bulb and capillary specifications, temperature accuracy, electrical ratings, cycle-life testing and applicable safety certifications (CE / CQC / UL). A high-limit safety thermostat must not be substituted on the basis of physical fit alone.