00-414880-00001 — K Type Fryer Thermostat, 96 in Capillary (Vulcan / Garland)

K-type fryer thermostat with knob, 200–400 °F, 5/16 in × 8-1/16 in nickel bulb, 96 in capillary. Used across Vulcan VF/VMF series and a range of Garland fryers.

Availability Status

Currently in production

Currently listed as a genuine OEM replacement part on PartsTown.

Source: public distributor listing, checked 2026-10-19. Availability changes; re-check before ordering.

Market Reference

OEM (quote only).

Source: public product listing at a major US parts retailer, checked 2026-10-20. This is a market observation for reference only — it is not an offer, a quotation, or a commitment to supply at any price.

Compatible Models

Vulcan

Garland

Welbilt

Cross-Reference / Interchange Part Numbers

This item is listed under the following part numbers across manufacturer documentation and distributor catalogs:

Cross-references marked as reported come from distributor interchange tables rather than manufacturer statements. Always verify against your equipment's parts manual before ordering.

Specifications

TypeK
Temperature range200–400 °F
Bulb5/16 in × 8-1/16 in, nickel
Capillary length96 in
Mount1
Dial options#22-1353 (indicator knob, 1-1/4 in dia.), #22-1191, #22-1006

What to Verify Before Ordering

These are the points that most often cause a wrong order on this specific part number. They are not generic advice.

Compiled from manufacturer catalog strings and distributor listings. Verify against your own equipment's parts manual before ordering. This is not an offer or a quotation.

How the sources word it

Distributor listing only. The K thermostat is the 5/16 in bulb unit with the long 96 in capillary, which is the number to match before substituting an RX or KX.

SourceWording (verbatim)What it isLink
SharpTek Supply listing (distributor wording, not OEM)“Thermostatk, 5/16 X 8-1/16, 96 for Hobart - Part# 00-414880-00001”Bulb diameter, bulb length and capillary length in the title.sharpteksupply.com

What it fits and where it is used

Controls fryer oil temperature where a long (96 in) capillary run is required — this is the longest capillary variant in this family, useful when the control panel is distant from the fry tank.

What it does and how it fails

A vapour-charged sensing bulb and capillary drive a diaphragm; the dial biases a set of contacts against it. There is no electronics inside. When a unit like this fails it fails in one of four ways: the contacts weld closed (heat keeps rising), the contacts open and stay open (no heat at all), the charge is lost through a cracked bulb or a kinked capillary (the unit behaves as if the oil is always cold), or the calibration drifts so the dial no longer matches the oil temperature. Only the last one still 'works' — which is why it is the one that quietly overcooks oil or trips the hi-limit.

Symptom check — is this control thermostat the cause?

SymptomThis part?Check first
Oil keeps climbing past the dial setting until the hi-limit tripsYes — contacts welded closedHi-limit continuity first; whether the burner stays lit with the dial turned to OFF
No heat, pilot or ignition sequence fine, dial turned upPossible — contacts open, or charge lostGas-valve operator signal, hi-limit continuity, ignition sequence
Dial setting and oil temperature disagree by more than a few degreesPossible — drift, or a fouled / mis-seated bulbBulb coating and immersion depth; cross-check the oil with a separate thermometer
Dial turns with no resistance, or no click at either end of the rangePossible — stripped shaft or detached capillaryCapillary routing at the stuffing box (kinks, crushed sections)

How to test it before you replace it

  1. Isolate gas and power, and cool the oil below 100 °F so the bulb is at room temperature.
  2. Disconnect the two wires at the thermostat and measure continuity across its terminals: at room temperature a healthy unit reads closed.
  3. Warm the bulb only — hot water or a heat gun on the bulb, never on the capillary — and watch for the contacts to open at the top of the 200–400 °F range.
  4. Cool the bulb and confirm the contacts close again. A unit that opens but never recloses leaves the fryer dead after one good cycle, and is often mistaken for a gas fault.
  5. Run a hand along the full capillary looking for kinks, flattened sections or a bulb that rattles. A damaged capillary cannot be repaired or recharged.
  6. and mounting.
These are standard electrical and gas-side checks for the device family, not a service manual for your fryer. Work with the appliance isolated, and have gas-side work done by a qualified fitter. Where this page states a value, it is copied from the specification table above; where it does not, the reading is only meaningful against your appliance manual.

Substitutions that fit but do not work

Related records and guides

Frequently Asked Questions

What does 00-414880-00001 fit?

Vulcan fryers (VF1, VF1D, VF90, VFD90, VMF1, VMF1D and the VF/VMF/VTMF families) and Garland fryers including 36ES series, 36FS-21, 680 series, 780 series, E22 and E24.

How long is the capillary?

96 inches — the longest variant in this thermostat family.

Is 414880-1 the same part?

Yes — 414880-1 is the same part number written without the 00- prefix.

China Sourcing Notes

Capillary, millivolt and high-limit thermostats in these part families are produced in volume in China. Public supplier directories list manufacturers concentrated in specific industrial clusters: Zhongshan (Guangdong) for capillary, millivolt and deep-fryer thermostats; Wenzhou (Zhejiang) for capillary, gas, immersion and mechanical thermostats with OEM/ODM capability; and Jinan (Shandong) for gas-valve and thermostatic gas-control components. When sourcing these parts from China, verify: dimensional drawings, sensing-bulb and capillary specifications, temperature accuracy, electrical ratings, cycle-life testing and applicable safety certifications (CE / CQC / UL). A high-limit safety thermostat must not be substituted on the basis of physical fit alone.

Sources & Compilation Note

Compiled from distributor catalogs (Zoro, RestaurantSupply, CAPP, PartsSource) and OEM parts documentation.

Part numbers and specifications are reproduced as published by the sources listed above. This page is a reference compilation for identification purposes. Last compiled: 2026-10-31.

Enquiry about this part

We reply by email. No account required. We do not share your details.