KX-type (dip sealed) fryer thermostat, 200–400 °F, 1/4 in × 12-1/8 in nickel bulb, 48 in capillary, 3/8 in MPT stuff box. Fits Vulcan fryers including the 7494E/7495E and GF/HF 91/92 series.
No listing returned for this number on PartsTown as of 2026-10-19 (may be superseded or handled under another channel).
Source: public distributor listing, checked 2026-10-19. Availability changes; re-check before ordering.
seen at $84.69, Non-OEM, made in Mexico.
Source: public product listing at a major US parts retailer, checked 2026-10-20. This is a market observation for reference only — it is not an offer, a quotation, or a commitment to supply at any price.
This item is listed under the following part numbers across manufacturer documentation and distributor catalogs:
00-410687-00001410687-00001410687-1110687-1111506-9VH410687-1VH110687-1VH111506-9| Type | KX (dip sealed) |
|---|---|
| Temperature range | 200–400 °F |
| Bulb | 1/4 in × 12-1/8 in, nickel |
| Capillary length | 48 in |
| Fitting | 3/8 in MPT stuff box |
| Mount | 1 |
| Dial | #22-1191 (black knob, white numbers, 2 in dia., OFF-400-200) |
These are the points that most often cause a wrong order on this specific part number. They are not generic advice.
Compiled from manufacturer catalog strings and distributor listings. Verify against your own equipment's parts manual before ordering. This is not an offer or a quotation.
Distributor specification only. The KX descriptor (dip sealed, 1/4 in bulb, 12-1/8 in long) is what separates it from the RX and K thermostats in the same range.
| Source | Wording (verbatim) | What it is | Link |
|---|---|---|---|
| PartsFe specification (distributor wording, not OEM) | “Type- Kx Dip Sealed · Temp 200-400 · Bulb 1/4" X - 12-1/8" Nickel · Cap 48"” | Body type, range, bulb and capillary length. | partsfe.com |
Controls fryer oil temperature on Vulcan fryers. The 48 in capillary allows the control to be mounted away from the fry tank.
A vapour-charged sensing bulb and capillary drive a diaphragm; the dial biases a set of contacts against it. There is no electronics inside. When a unit like this fails it fails in one of four ways: the contacts weld closed (heat keeps rising), the contacts open and stay open (no heat at all), the charge is lost through a cracked bulb or a kinked capillary (the unit behaves as if the oil is always cold), or the calibration drifts so the dial no longer matches the oil temperature. Only the last one still 'works' — which is why it is the one that quietly overcooks oil or trips the hi-limit.
| Symptom | This part? | Check first |
|---|---|---|
| Oil keeps climbing past the dial setting until the hi-limit trips | Yes — contacts welded closed | Hi-limit continuity first; whether the burner stays lit with the dial turned to OFF |
| No heat, pilot or ignition sequence fine, dial turned up | Possible — contacts open, or charge lost | Gas-valve operator signal, hi-limit continuity, ignition sequence |
| Dial setting and oil temperature disagree by more than a few degrees | Possible — drift, or a fouled / mis-seated bulb | Bulb coating and immersion depth; cross-check the oil with a separate thermometer |
| Dial turns with no resistance, or no click at either end of the range | Possible — stripped shaft or detached capillary | Capillary routing at the stuffing box (kinks, crushed sections) |
Vulcan fryers including 7494E, 7495E, GF91E, GF92E, HF91E and HF92E (former model numbers 7891E and 7892E).
1/4 in × 12-1/8 in nickel bulb with a 48 in capillary.
Distributor tables report 111506-9 as an interchangeable number for this thermostat.
Capillary, millivolt and high-limit thermostats in these part families are produced in volume in China. Public supplier directories list manufacturers concentrated in specific industrial clusters: Zhongshan (Guangdong) for capillary, millivolt and deep-fryer thermostats; Wenzhou (Zhejiang) for capillary, gas, immersion and mechanical thermostats with OEM/ODM capability; and Jinan (Shandong) for gas-valve and thermostatic gas-control components. When sourcing these parts from China, verify: dimensional drawings, sensing-bulb and capillary specifications, temperature accuracy, electrical ratings, cycle-life testing and applicable safety certifications (CE / CQC / UL). A high-limit safety thermostat must not be substituted on the basis of physical fit alone.
Compiled from Vulcan-oriented parts catalogs (PartsFe, KitchenRestock, Global Commercial Parts, RestaurantSupply).
Part numbers and specifications are reproduced as published by the sources listed above. This page is a reference compilation for identification purposes. Last compiled: 2026-10-31.