00-410841-00022 & 00-410841-00023 — Millivolt Combination Gas Valve (Vulcan EF / GR / 1GR, Hobart 1HG)

The standard millivolt combination gas valve on Vulcan EF, GR, GRD, GRMF and 1GR fryers and Hobart 1HG-M series fryers. Robertshaw 7000BMVR (catalog 700-504): 1/2 in FPT inlet, 3/4 in straight-through outlet plus two plugged 1/2 in side outlets, 1/4 in CCT pilot outlet, 3.5 in WC natural-gas regulator adjustable 3–7 in WC, 240,000 BTU. LP version 00-410841-00023 uses kit 51-1470.

Availability Status

Currently in production

Active with stock at multiple US distributors as of 2026-10-20 (Parts Town listed 32 units). This is the highest-fitment gas valve in the ITW fryer range.

Source: public distributor listing, checked 2026-10-19. Availability changes; re-check before ordering.

Market Reference

seen at $241.49, Non-OEM, made in Mexico. 5+ units sold in recent months.

Source: public product listing at a major US parts retailer, checked 2026-10-20. This is a market observation for reference only — it is not an offer, a quotation, or a commitment to supply at any price.

Compatible Models

Vulcan

Hobart

Cross-Reference / Interchange Part Numbers

This item is listed under the following part numbers across manufacturer documentation and distributor catalogs:

Cross-references marked as reported come from distributor interchange tables rather than manufacturer statements. Always verify against your equipment's parts manual before ordering.

Specifications

TypeMillivolt combination gas valve, wall-thermostat actuated
OperatorMillivolt, 250–750 mV
Inlet1/2 in FPT
Outlet3/4 in straight-through plus two plugged 1/2 in side outlets; 1/4 in CCT pilot outlet
Regulator3.5 in WC natural gas, adjustable 3–7 in WC
Capacity240,000 BTU
Gas cockOff – Pilot – On
Maximum inlet14 in WC
LP conversionKit 51-1470
Direct Robertshaw equivalent700-504 (7000BMVR)

What to Verify Before Ordering

These are the points that most often cause a wrong order on this specific part number. They are not generic advice.

Compiled from manufacturer catalog strings and distributor listings. Verify against your own equipment's parts manual before ordering. This is not an offer or a quotation.

As the OEM parts catalog lists it

The OEM catalog lists this number as a combination valve for natural gas. According to FORM F-37136 Rev. A (January 2024) the line reads “00-410841-00022 Combination Valve (Nat. Gas)”, with the LP equivalent on the next line as a separate number.

ItemPart no.Name of part (verbatim)Amt
2100-410841-00022Combination Valve (Nat. Gas)—

Source: Vulcan-Hart, LG Series Fryers replacement parts catalog, FORM F-37136 Rev. A (January 2024), Manifold assembly, p. 11. Retrieved 2026-10-27: https://www.webstaurantstore.com/documents/pdf/lg_series_fryer_gas_parts_catalog_f37136_02-24_.pdf. Quoted under fair use for identification; the manual is the publisher's document.

What it fits and where it is used

Pilot safety and main-burner gas regulation on the mainstream Vulcan gas fryer lines (EF3/EF4/EF5, GR/GRC/GRD/GRMF, 1GR, 2GR–4GR) and on Hobart 1HG-M series fryers. This is the highest-fitment gas valve in the ITW fryer range — distributor catalogs list it against dozens of models.

What it does and how it fails

A combination valve: a safety magnet held by the pilot's thermopile, a diaphragm operator that the thermostat opens, a pressure regulator and a gas cock in one body. This is a millivolt valve — the thermostat switches millivolts, not mains voltage. Most 'bad valve' diagnoses are really a missing call, a weak thermopile or a dirty inlet screen.

Symptom check — is this millivolt gas valve the cause?

SymptomThis part?Check first
Ignition sequence runs, main burner never lightsPossible — operator not pulling inCall signal at the operator terminals, then inlet pressure
Burner lights and then drops outPossible — safety circuit losing holdThermopile output under load, terminal condition, pilot flame quality
Burner stays on after the call endsYes — operator stuck open (safety)Stop using the fryer; verify with the call removed before replacing anything
Valve chatters or buzzesPossible — low operating signalSupply voltage / millivolts, loose spade terminals, corroded ground

How to test it before you replace it

  1. Confirm the call: at the operator terminals measure DC millivolts while the thermostat is turned up. No signal means the valve is being blamed for an upstream fault.
  2. Measure inlet pressure with a manometer (a licensed gas fitter's job, not a multimeter job) and compare it with the maximum inlet on this record: 14 in WC.
  3. Check the regulator setting against this record (3.5 in WC natural gas, adjustable 3–7 in WC) and confirm the spring matches the gas being used.
  4. Inspect the inlet screen and the pilot outlet for debris; a blocked pilot outlet gives a flame that looks fine but does not play on the thermopile.
  5. If the valve is being replaced, match inlet/outlet, capacity and porting — not just the footprint.
These are standard electrical and gas-side checks for the device family, not a service manual for your fryer. Work with the appliance isolated, and have gas-side work done by a qualified fitter. Where this page states a value, it is copied from the specification table above; where it does not, the reading is only meaningful against your appliance manual.

Substitutions that fit but do not work

Related records and guides

Frequently Asked Questions

Is 00-410841-00022 the same as Robertshaw 700-504?

Yes — 00-410841-00022 is the ITW/Vulcan number for the Robertshaw 7000BMVR, catalog number 700-504.

Does it fit Vulcan VF or VMF fryers?

No. VF1, VMF1, VF90, VFD90 and related VF/VMF models are electric fryers and have no gas valve. Use the EF / GR / 1GR / 1HG lines for gas fitment.

What is the difference between -00022 and -00023?

-00022 is the natural-gas build; -00023 is the same valve in propane build. Both share the 51-1470 conversion kit.

What is the maximum gas inlet pressure?

14 in WC.

China Sourcing Notes

Capillary, millivolt and high-limit thermostats in these part families are produced in volume in China. Public supplier directories list manufacturers concentrated in specific industrial clusters: Zhongshan (Guangdong) for capillary, millivolt and deep-fryer thermostats; Wenzhou (Zhejiang) for capillary, gas, immersion and mechanical thermostats with OEM/ODM capability; and Jinan (Shandong) for gas-valve and thermostatic gas-control components. When sourcing these parts from China, verify: dimensional drawings, sensing-bulb and capillary specifications, temperature accuracy, electrical ratings, cycle-life testing and applicable safety certifications (CE / CQC / UL). A high-limit safety thermostat must not be substituted on the basis of physical fit alone.

Sources & Compilation Note

Compiled from Vulcan OEM parts manual F30795 (EF3, item 21), Hobart OEM parts manual F-43118 (1HG series), Parts Town fitment data, and Robertshaw 700-504 catalog specifications.

Part numbers and specifications are reproduced as published by the sources listed above. This page is a reference compilation for identification purposes. Last compiled: 2026-10-31.

Enquiry about this part