00-410841-00001 & 00-410841-00002 — Vulcan GHF Series Millivolt Gas Valve (NG / LP)

OEM Vulcan combination gas valve for GHF Series heavy-duty fryers built before June 1998. Millivolt, thermopile-driven safety valve (Robertshaw 7000BMSGOR / 700-886): 3/4 in FPT inlet and outlet, 1/4 in CCT pilot outlet, 3.5 in WC natural-gas regulator, 300,000 BTU. The LP version (00-410841-00002) uses the same body with LP conversion kit 51-1470.

Availability Status

Currently in production

Listed as active and in stock at major US distributors as of 2026-10-20. Not discontinued - the GHF-series change is date-based (pre-/post-06/1998), not a supersession.

Source: public distributor listing, checked 2026-10-19. Availability changes; re-check before ordering.

Market Reference

seen at $350.90, Non-OEM, made in Mexico.

Source: public product listing at a major US parts retailer, checked 2026-10-20. This is a market observation for reference only — it is not an offer, a quotation, or a commitment to supply at any price.

Compatible Models

Vulcan

Not applicable

Cross-Reference / Interchange Part Numbers

This item is listed under the following part numbers across manufacturer documentation and distributor catalogs:

Cross-references marked as reported come from distributor interchange tables rather than manufacturer statements. Always verify against your equipment's parts manual before ordering.

Specifications

TypeMillivolt combination gas valve (bleed-gas safety valve, thermopile-driven diaphragm)
OperatorThermopile, 750 mV open circuit / 500 mV under load
Inlet / outlet3/4 in FPT in and out; 1/4 in CCT pilot out; 3/4 in × 1/2 in reducer bushings included
Regulator3.5 in WC natural gas; 0.5 psi maximum inlet
Capacity300,000 BTU
Gas cockOff – Pilot – On
Thermopile fitmentScrew-in type: H231 / T-103 / 51-1122
LP conversionKit 51-1470 (same valve body, different regulator spring)
Robertshaw equivalent7000BMSGOR / 700-886

What to Verify Before Ordering

These are the points that most often cause a wrong order on this specific part number. They are not generic advice.

Compiled from manufacturer catalog strings and distributor listings. Verify against your own equipment's parts manual before ordering. This is not an offer or a quotation.

How the sources word it

No OEM catalogue page for this exact number was reachable. The decisive detail is that the valve is a bleed-gas actuator running a slotted thermopile magnet — there is no 24 V terminal on it.

SourceWording (verbatim)What it isLink
PizzaOvens specification (distributor wording, not OEM)“Nat Gas · Size 3/4" Fpt · Nat Safety · 3.5"Wc · Bleed Gas Actuator · Brand Rsw · 1/4" Cct Pilot Out Only, W/Slotted Thermopile Magnet · Model 7000 Bmsgor”Bleed-gas actuator and thermopile magnet — the millivolt architecture, stated in the spec string.pizzaovens.com

What it fits and where it is used

Gas safety and temperature regulation on Vulcan GHF Series heavy-duty gas fryers built before June 1998. The valve holds the pilot, and once the thermopile reaches operating voltage it permits main-burner gas flow under wall-thermostat control. The LP variant 00-410841-00002 is the same casting with propane regulator internals.

What it does and how it fails

A combination valve: a safety magnet held by the pilot's thermopile, a diaphragm operator that the thermostat opens, a pressure regulator and a gas cock in one body. This is a millivolt valve — the thermostat switches millivolts, not mains voltage. Most 'bad valve' diagnoses are really a missing call, a weak thermopile or a dirty inlet screen.

Symptom check — is this millivolt gas valve the cause?

SymptomThis part?Check first
Ignition sequence runs, main burner never lightsPossible — operator not pulling inCall signal at the operator terminals, then inlet pressure
Burner lights and then drops outPossible — safety circuit losing holdThermopile output under load, terminal condition, pilot flame quality
Burner stays on after the call endsYes — operator stuck open (safety)Stop using the fryer; verify with the call removed before replacing anything
Valve chatters or buzzesPossible — low operating signalSupply voltage / millivolts, loose spade terminals, corroded ground

How to test it before you replace it

  1. Confirm the call: at the operator terminals measure DC millivolts while the thermostat is turned up. No signal means the valve is being blamed for an upstream fault.
  2. Measure inlet pressure with a manometer (a licensed gas fitter's job, not a multimeter job) and compare it with the maximum inlet on this record: 3/4 in FPT in and out; 1/4 in CCT pilot out; 3/4 in × 1/2 in reducer bushings included.
  3. Check the regulator setting against this record (3.5 in WC natural gas; 0.5 psi maximum inlet) and confirm the spring matches the gas being used.
  4. Inspect the inlet screen and the pilot outlet for debris; a blocked pilot outlet gives a flame that looks fine but does not play on the thermopile.
  5. If the valve is being replaced, match inlet/outlet, capacity and porting — not just the footprint.
These are standard electrical and gas-side checks for the device family, not a service manual for your fryer. Work with the appliance isolated, and have gas-side work done by a qualified fitter. Where this page states a value, it is copied from the specification table above; where it does not, the reading is only meaningful against your appliance manual.

Substitutions that fit but do not work

Related records and guides

Frequently Asked Questions

Does 00-410841-00001 fit all Vulcan fryers?

No. The OEM listing limits it to GHF91E, GHF92E, GHF91G and GHF92G fryers built before June 1998. Later GHF builds and the EF / GR / 1GR / 1HG lines use 00-410841-00022 instead.

Can it be converted to propane?

Yes — kit 51-1470 converts the valve to LP. 00-410841-00002 is the factory LP version of the same valve.

What thermopile goes with it?

A screw-in thermopile of the H231 / T-103 / 51-1122 type. The valve expects roughly 750 mV open circuit and about 500 mV under load.

Is 412196 a like-for-like substitute?

No — do not treat 412196 as a direct equivalent for this valve.

China Sourcing Notes

Capillary, millivolt and high-limit thermostats in these part families are produced in volume in China. Public supplier directories list manufacturers concentrated in specific industrial clusters: Zhongshan (Guangdong) for capillary, millivolt and deep-fryer thermostats; Wenzhou (Zhejiang) for capillary, gas, immersion and mechanical thermostats with OEM/ODM capability; and Jinan (Shandong) for gas-valve and thermostatic gas-control components. When sourcing these parts from China, verify: dimensional drawings, sensing-bulb and capillary specifications, temperature accuracy, electrical ratings, cycle-life testing and applicable safety certifications (CE / CQC / UL). A high-limit safety thermostat must not be substituted on the basis of physical fit alone.

Sources & Compilation Note

Compiled from Vulcan OEM parts manuals (GHF series), Parts Town and PizzaOvens distributor listings, and Robertshaw catalog data for the 7000BMSGOR / 700-886 valve.

Part numbers and specifications are reproduced as published by the sources listed above. This page is a reference compilation for identification purposes. Last compiled: 2026-10-31.

Enquiry about this part

We reply by email. No account required. We do not share your details.