LC117 high-limit safety thermostat with auto reset, fixed 450 °F cut-out, 1/4 in × 4-7/8 in nickel bulb, 30 in capillary, 3/8 in MPT nickel stuff box.
PartsTown lists this number as Obsolete and superseded by 00-410840-00002.
Successor part number: 00-410840-00002
Source: public distributor listing, checked 2026-10-19. Availability changes; re-check before ordering.
seen at $137.99, Non-OEM, made in United States. 15+ units sold in recent months.
Source: public product listing at a major US parts retailer, checked 2026-10-20. This is a market observation for reference only — it is not an offer, a quotation, or a commitment to supply at any price.
This item is listed under the following part numbers across manufacturer documentation and distributor catalogs:
00-419670-00001419670-00001419670-18047354735721029-00001721029-1119670-121029-1AB-6753AB-6962| Type | LC117 Hi-Limit, auto reset |
|---|---|
| Cut-out temperature | 450 °F (fixed) |
| Bulb | 1/4 in × 4-7/8 in, nickel |
| Capillary length | 30 in |
| Fitting | 3/8 in MPT stuff box, nickel |
| Enclosure | 7 in × 1.5 in × 1.5 in |
These are the points that most often cause a wrong order on this specific part number. They are not generic advice.
Compiled from manufacturer catalog strings and distributor listings. Verify against your own equipment's parts manual before ordering. This is not an offer or a quotation.
Distributor specification. The LC117 is stated as auto-reset with a 450 F cut-out — the counterpart of the manual-reset LCH, and the distinction that decides whether a swap is safe.
| Source | Wording (verbatim) | What it is | Link |
|---|---|---|---|
| PartsFe specification (distributor wording, not OEM) | “Hi-Limit Type - Lc117 W/Auto Reset · Temp 450 · Bulb 1/4" X 4-7/8" Nickel · Cap 30" · Size 3/8" Mpt Stuff Box, Nickel” | Reset type, set point, bulb and capillary. | partsfe.com |
Safety cut-out that switches off fryer heating if oil temperature exceeds 450 °F. Auto-reset type — it resets itself once temperature falls, unlike manual-reset hi-limit devices.
A fixed-set-point safety switch with its own sensing bulb. It does not control temperature: it removes the circuit when the sensed temperature passes a limit the appliance must not exceed. This one is auto reset — it recloses as the bulb cools, which means the fryer can restart itself after an overheat event without anyone noticing why it stopped.
| Symptom | This part? | Check first |
|---|---|---|
| Fryer dead after an overheat event, pilot or ignition fine | Yes — the device is open | On a manual-reset unit press the button once; then find the cause before running a service |
| Trips again within a service cycle | No — it is doing its job | Oil level, coated bulb, blocked flue, ventilation, gas-valve overfiring, control thermostat not cycling |
| Oil smokes or smells burnt before it trips | No | Control thermostat calibration or a mis-seated control bulb |
| Trips with cold oil at start-up | Possible — wrong set point, or a failing device | Compare the stamped cut-out with the appliance manual and check the wiring holding the circuit |
Vulcan fryers including 7494E, 7495E, 7594G, 7595G, HF91/HF92 series, TK-35 and TK-45, plus GRC/GRD/GRS/GR family fryers; Broaster fryers; and Wolf WTF-35.
Auto reset, with a fixed 450 °F cut-out.
No — 419670-1 is the same number without the 00- prefix.
Capillary, millivolt and high-limit thermostats in these part families are produced in volume in China. Public supplier directories list manufacturers concentrated in specific industrial clusters: Zhongshan (Guangdong) for capillary, millivolt and deep-fryer thermostats; Wenzhou (Zhejiang) for capillary, gas, immersion and mechanical thermostats with OEM/ODM capability; and Jinan (Shandong) for gas-valve and thermostatic gas-control components. When sourcing these parts from China, verify: dimensional drawings, sensing-bulb and capillary specifications, temperature accuracy, electrical ratings, cycle-life testing and applicable safety certifications (CE / CQC / UL). A high-limit safety thermostat must not be substituted on the basis of physical fit alone.
Compiled from AllPoints specification data (48-1011), distributor catalogs (PartsFe, Direct Brand, Voomi Supply, Restaurant and More) and vendor OEM-name/part-number matrices.
Part numbers and specifications are reproduced as published by the sources listed above. This page is a reference compilation for identification purposes. Last compiled: 2026-10-31.