24 V combination safety valve for electronic-ignition fryers, including Hobart 1HGC / 1HGD. Robertshaw 700-049 / 7000BDER-S7A: 1/2 in FPT inlet and outlet, 1/4 in CCT pilot outlet, 300,000 BTU, natural gas with LP conversion kit 51-1184.
Listed as active at US distributors as of 2026-10-20. 24 V electronic-ignition build; not interchangeable with the millivolt valves on the other pages.
Source: public distributor listing, checked 2026-10-19. Availability changes; re-check before ordering.
This item is listed under the following part numbers across manufacturer documentation and distributor catalogs:
00-410841-0002800-410841-00029Robertshaw 700-049Robertshaw 7000BDER-S7A51-1184| Type | 24 V combination gas valve for electronic ignition |
|---|---|
| Supply | 24 V AC 60 Hz / 12 V DC |
| Inlet / outlet | 1/2 in FPT in and out; 1/4 in CCT pilot outlet |
| Capacity | 300,000 BTU |
| Maximum inlet | 14 in WC |
| LP conversion | Kit 51-1184 |
| Robertshaw equivalent | 700-049 / 7000BDER-S7A |
| Regulator setpoint | Not published consistently — sources disagree (3.0 in WC vs 3.5 in WC). Verify against your unit before ordering. |
These are the points that most often cause a wrong order on this specific part number. They are not generic advice.
Compiled from manufacturer catalog strings and distributor listings. Verify against your own equipment's parts manual before ordering. This is not an offer or a quotation.
Distributor specification. The 24 V side of the family is stated as 24Vac/12Vdc and is meant for intermittent pilot, direct spark and hot-surface ignition — not for a standing pilot with a thermopile.
| Source | Wording (verbatim) | What it is | Link |
|---|---|---|---|
| PizzaOvens specification (distributor wording, not OEM) | “Nat Gas · Size 1/2" Fpt · Nat Safety · 3.5"Wc · 24Vac/12Vdc · Brand Rs Mfg# 700-049 · For Intermittant Pilot, Direct Spark, And Hot Surface.” | Voltage and ignition type, in one line. | pizzaovens.com |
Gas safety and regulation on electronic-ignition fryers — intermittent pilot, direct spark and hot-surface ignition systems. Used on Hobart 1HGC/1HGD fryers and on Vulcan GRD electronic-ignition builds.
A combination valve: a safety magnet held by the ignition board's flame signal, a diaphragm operator that the board opens, a pressure regulator and a gas cock in one body. This is a 24 V AC valve for electronic ignition — it is opened by the ignition board, not by a millivolt thermostat. Most 'bad valve' diagnoses are really a missing call, a weak thermopile or a dirty inlet screen.
| Symptom | This part? | Check first |
|---|---|---|
| Ignition sequence runs, main burner never lights | Possible — operator not pulling in | Call signal at the operator terminals, then inlet pressure |
| Burner lights and then drops out | Possible — safety circuit losing hold | Flame-sense signal and sensor condition |
| Burner stays on after the call ends | Yes — operator stuck open (safety) | Stop using the fryer; verify with the call removed before replacing anything |
| Valve chatters or buzzes | Possible — low operating signal | Supply voltage / millivolts, loose spade terminals, corroded ground |
-00028 is the natural-gas build and -00029 the propane build of the same 24 V valve.
No. A 24 V electronic-ignition valve and a millivolt valve are not interchangeable — the ignition systems differ.
Published sources disagree (3.0 in WC vs 3.5 in WC). Confirm against the data plate of your fryer rather than relying on a catalog value.
Capillary, millivolt and high-limit thermostats in these part families are produced in volume in China. Public supplier directories list manufacturers concentrated in specific industrial clusters: Zhongshan (Guangdong) for capillary, millivolt and deep-fryer thermostats; Wenzhou (Zhejiang) for capillary, gas, immersion and mechanical thermostats with OEM/ODM capability; and Jinan (Shandong) for gas-valve and thermostatic gas-control components. When sourcing these parts from China, verify: dimensional drawings, sensing-bulb and capillary specifications, temperature accuracy, electrical ratings, cycle-life testing and applicable safety certifications (CE / CQC / UL). A high-limit safety thermostat must not be substituted on the basis of physical fit alone.
Compiled from ITW/FEG OEM parts listings, distributor catalogs, and Robertshaw 700-049 / 7000BDER-S7A specification data.
Part numbers and specifications are reproduced as published by the sources listed above. This page is a reference compilation for identification purposes. Last compiled: 2026-10-31.