# Fryer Thermostat Parts Reference > Free, non-commercial reference index of commercial deep-fryer part numbers, interchange cross-references, specifications and compatible fryer models. No own prices, no stock, no offers; a third-party price, where quoted, is labelled "Market Reference" with its source and the date it was checked. Site: https://fryerparts.pages.dev — Data licence: CC0 1.0 — Dataset DOI: https://doi.org/10.5281/zenodo.23613053 Corrections: https://fryerparts.pages.dev/#enquiry (form only — no public email). No sales contact. Scope: 16 part records — a reference index of the families listed below, not a catalogue of all commercial fryer parts. Last updated: 2026-11-02 Read-only reference. Fitment is cross-referenced, not certified. A hi-limit safety device must not be substituted on dimensional fit alone. ## Part number records - [00-348358-00001 & 00-410839-00001 — 36 in Coaxial Thermopile, 250–750 mV](https://fryerparts.pages.dev/parts/00-348358-00001-coaxial-thermopile-36in/): 36-inch coaxial thermopile, 250–750 mV, 3/8-32 mounting thread — the Robertshaw 1951-53F type used on Vulcan GR-series fryers and Wolf fryers and grills. - [00-348361-00001 — Fenwal Fryer Thermostat, 75–550 °F, 1/2 in NPT](https://fryerparts.pages.dev/parts/00-348361-00001-fenwal-thermostat/): Fenwal thermostat with melt/melting function, 75–550 °F range, wire leads (2 × 1/4 in female push-on), 1/2 in NPT mounting, 4-3/4 in probe. - [00-410687-00001 — KX Type Fryer Thermostat (Vulcan)](https://fryerparts.pages.dev/parts/00-410687-00001-kx-thermostat/): KX-type (dip sealed) fryer thermostat, 200–400 °F, 1/4 in × 12-1/8 in nickel bulb, 48 in capillary, 3/8 in MPT stuff box. - [00-410839-00004 & 721027-1 — 36 in Two-Lead Thermopile, 250–750 mV](https://fryerparts.pages.dev/parts/00-410839-00004-two-lead-thermopile-36in/): 36-inch two-lead millivolt thermopile (Robertshaw 1950-53B type) used on current Vulcan LG, VEG and 1GR fryers. - [00-410841-00001 & 00-410841-00002 — Vulcan GHF Series Millivolt Gas Valve (NG / LP)](https://fryerparts.pages.dev/parts/00-410841-00001-gas-valve-ghf-millivolt/): OEM Vulcan combination gas valve for GHF Series heavy-duty fryers built before June 1998. - [00-410841-00022 & 00-410841-00023 — Millivolt Combination Gas Valve (Vulcan EF / GR / 1GR, Hobart 1HG)](https://fryerparts.pages.dev/parts/00-410841-00022-gas-valve-millivolt-standard/): The standard millivolt combination gas valve on Vulcan EF, GR, GRD, GRMF and 1GR fryers and Hobart 1HG-M series fryers. - [00-410841-00028 & 00-410841-00029 — 24 V Combination Gas Valve, Electronic Ignition](https://fryerparts.pages.dev/parts/00-410841-00028-gas-valve-24v-electronic/): 24 V combination safety valve for electronic-ignition fryers, including Hobart 1HGC / 1HGD. - [00-411506-00013 — RX Type Fryer Thermostat Kit (Hobart / Vulcan)](https://fryerparts.pages.dev/parts/00-411506-00013-rx-thermostat/): RX-type thermostat kit with knob and screws for Hobart 1HG series gas fryers and Vulcan/Wolf fryers. - [00-414146-00002 — LCH Hi-Limit Thermostat, Manual Reset, 435 °F (Hobart 1HF)](https://fryerparts.pages.dev/parts/00-414146-00002-lch-hi-limit-thermostat/): LCH high-limit thermostat with manual reset, fixed 435 °F cut-out, 1/4 in × 4-7/8 in nickel bulb, 24 in capillary. - [00-414880-00001 — K Type Fryer Thermostat, 96 in Capillary (Vulcan / Garland)](https://fryerparts.pages.dev/parts/00-414880-00001-k-thermostat/): K-type fryer thermostat with knob, 200–400 °F, 5/16 in × 8-1/16 in nickel bulb, 96 in capillary. - [00-419670-00001 — LC117 Hi-Limit Safety Thermostat, Auto Reset, 450 °F](https://fryerparts.pages.dev/parts/00-419670-00001-lc117-hi-limit-thermostat/): LC117 high-limit safety thermostat with auto reset, fixed 450 °F cut-out, 1/4 in × 4-7/8 in nickel bulb, 30 in capillary, 3/8 in MPT nickel stuff box. - [00-959500-00001 — Gas Ignitor Board (Vulcan VK / TR / VFRY Fryers, Built After 12/2012)](https://fryerparts.pages.dev/parts/00-959500-00001-gas-ignitor-board/): Board-level gas ignition module mounted in the power supply box of Vulcan VK and TR series fryers built after 1 December 2012, and on VFRY series fryers. - [RTCU700609 & RTBF800164 — Hobart HEF47 / HEF77 Fryer Thermostats (European Range)](https://fryerparts.pages.dev/parts/rtcu700609-rtbf800164-hef47-fryer-thermostats/): European-range Hobart fryer thermostats: RTCU700609 electronic control thermostat (105–185 °C, ⌀6 mm × 130 mm probe, 900 mm capillary) and RTBF800164 limit thermostat… ## Heating element records - [12000W Fryer Element Assemblies — Hobart HFD85 / HFC85 & Vulcan 85-Series](https://fryerparts.pages.dev/elements/12000w-fryer-element-85lb-series/): 12000 W (12 kW) element assemblies for 85 lb electric fryers, supplied in three voltage-specific part numbers: 208 V (00-421892-000G1), 240 V (00-421892-000G3) and 480… - [240V 5500W Fryer Element — Hobart HK3 / HK31 Series](https://fryerparts.pages.dev/elements/240v-5500w-fryer-element/): 240 V, 5500 W single-phase fryer heating element with flag terminals and 5/8"-18 mounting thread, for Hobart HK3 / HK31 series fryers (Vulcan equivalent number 351306-… - [8500W Fryer Element Assemblies — Hobart HFD50 / HFC50 & Vulcan 50-Series](https://fryerparts.pages.dev/elements/8500w-fryer-element-50lb-series/): 8500 W element assemblies for 50 lb electric fryers, supplied in three voltage-specific part numbers: 208 V (00-416741-000G9), 240 V (00-416741-00G11) and 480 V (00-41… ## Guides - [Fryer Hi-Limit Thermostat: The Five Numbers That Decide Fit](https://fryerparts.pages.dev/guides/fryer-hi-limit-thermostat-fit-guide/): Two hi-limit thermostats can share a function, a temperature and a thread and still not fit. - [Fryer Keeps Tripping the Hi-Limit: What to Check Before You Buy the Part](https://fryerparts.pages.dev/guides/fryer-keeps-tripping-hi-limit-diagnosis/): A fryer that shuts itself off mid-service is usually reported as a failed thermostat. - [Why the Same Fryer Part Costs More Under an OEM Label](https://fryerparts.pages.dev/guides/oem-vs-aftermarket-fryer-parts-price-gap/): The same number, three listings, $135.02 to $233.04. - [Where to Buy Discontinued Commercial Fryer Parts (2026)](https://fryerparts.pages.dev/guides/where-to-buy-discontinued-fryer-parts/): Discontinued by the OEM does not mean gone. ## Comparisons - [Can I replace 00-419670-00001 with 00-410840-00002?](https://fryerparts.pages.dev/compare/00-419670-00001-vs-00-410840-00002/): Usually yes, but check the sensing bulb first. - [Can I use an 8500 W element in place of a 5500 W element?](https://fryerparts.pages.dev/compare/5500w-vs-8500w-element/): No. - [Can I use the two-lead thermopile (00-410839-00004) instead of the coaxial one (00-348358-00001)?](https://fryerparts.pages.dev/compare/coaxial-vs-two-lead-thermopile/): No. - [Is the non-OEM version of 00-348361-00001 the same as the Hobart-branded one?](https://fryerparts.pages.dev/compare/fenwal-oem-vs-aftermarket/): Possibly - and that is the point. - [Can I use the LCH hi-limit (00-414146-00002) instead of the LC117 (00-419670-00001)?](https://fryerparts.pages.dev/compare/lc117-vs-lch-hi-limit/): No. - [Can I use the 24 V electronic-ignition gas valve (00-410841-00028) in place of a millivolt valve (00-410841-00001)?](https://fryerparts.pages.dev/compare/millivolt-vs-24v-gas-valve/): No. - [Can I use the natural-gas valve (00-410841-00001) on LP?](https://fryerparts.pages.dev/compare/ng-vs-lp-gas-valve/): No, not without the LP conversion kit. - [Are RTCU700609 and RTBF800164 the same thermostat?](https://fryerparts.pages.dev/compare/rtcu700609-vs-rtbf800164/): No. - [Is 00-913153 the same part as 00-411506-00013?](https://fryerparts.pages.dev/compare/rx-kit-vs-913153/): Distributor interchange tables treat 00-913153 as the current number for the same RX thermostat kit. - [What is the difference between the RX, KX and K fryer thermostats?](https://fryerparts.pages.dev/compare/rx-vs-kx-vs-k-thermostat/): They are three different thermostat families with different bulb diameters, capillary lengths and temperature ranges. ## Guides (diagnostic and fitment) - [Where to Buy Discontinued Commercial Fryer Parts (2026)](https://fryerparts.pages.dev/guides/where-to-buy-discontinued-fryer-parts/): Discontinued by the OEM does not mean gone. - [Why the Same Fryer Part Costs More Under an OEM Label](https://fryerparts.pages.dev/guides/oem-vs-aftermarket-fryer-parts-price-gap/): The same number, three listings, $135.02 to $233.04. - [Fryer Hi-Limit Thermostat: The Five Numbers That Decide Fit](https://fryerparts.pages.dev/guides/fryer-hi-limit-thermostat-fit-guide/): Two hi-limit thermostats can share a function, a temperature and a thread and still not fit. - [Fryer Keeps Tripping the Hi-Limit: What to Check Before You Buy the Part](https://fryerparts.pages.dev/guides/fryer-keeps-tripping-hi-limit-diagnosis/): A fryer that shuts itself off mid-service is usually reported as a failed thermostat. ## Comparisons (part vs part) - [Can I use the LCH hi-limit (00-414146-00002) instead of the LC117 (00-419670-00001)?](https://fryerparts.pages.dev/compare/lc117-vs-lch-hi-limit/): No. - [Can I use the two-lead thermopile (00-410839-00004) instead of the coaxial one (00-348358-00001)?](https://fryerparts.pages.dev/compare/coaxial-vs-two-lead-thermopile/): No. - [Can I replace 00-419670-00001 with 00-410840-00002?](https://fryerparts.pages.dev/compare/00-419670-00001-vs-00-410840-00002/): Usually yes, but check the sensing bulb first. - [Is 00-913153 the same part as 00-411506-00013?](https://fryerparts.pages.dev/compare/rx-kit-vs-913153/): Distributor interchange tables treat 00-913153 as the current number for the same RX thermostat kit. - [Is the non-OEM version of 00-348361-00001 the same as the Hobart-branded one?](https://fryerparts.pages.dev/compare/fenwal-oem-vs-aftermarket/): Possibly - and that is the point. - [Are RTCU700609 and RTBF800164 the same thermostat?](https://fryerparts.pages.dev/compare/rtcu700609-vs-rtbf800164/): No. - [Can I use the 24 V electronic-ignition gas valve (00-410841-00028) in place of a millivolt valve (00-410841-00001)?](https://fryerparts.pages.dev/compare/millivolt-vs-24v-gas-valve/): No. - [Can I use an 8500 W element in place of a 5500 W element?](https://fryerparts.pages.dev/compare/5500w-vs-8500w-element/): No. - [Can I use the natural-gas valve (00-410841-00001) on LP?](https://fryerparts.pages.dev/compare/ng-vs-lp-gas-valve/): No, not without the LP conversion kit. - [What is the difference between the RX, KX and K fryer thermostats?](https://fryerparts.pages.dev/compare/rx-vs-kx-vs-k-thermostat/): They are three different thermostat families with different bulb diameters, capillary lengths and temperature ranges. ## Site - [All part numbers](https://fryerparts.pages.dev/): index of every record - [Heating elements](https://fryerparts.pages.dev/elements/): elements by voltage and wattage - [Guides](https://fryerparts.pages.dev/guides/): diagnostic and fitment guides - [Comparisons](https://fryerparts.pages.dev/compare/): part-vs-part and OEM-vs-aftermarket - [Sources & method](https://fryerparts.pages.dev/sources/): how the data was compiled and what was not verified ## Machine-readable - [Data index](https://fryerparts.pages.dev/data/index.json): endpoint list, field descriptions, record count - [All records](https://fryerparts.pages.dev/data/parts.json): every record as JSON, same fields as the pages - [Price observations](https://fryerparts.pages.dev/data/prices.json): every price this site prints, with the date it was read and the page it came from - [One record](https://fryerparts.pages.dev/data/parts/.json): single record by slug - [OpenAPI 3.1](https://fryerparts.pages.dev/openapi.json): the three read-only JSON endpoints, for agents without an MCP client - [Search endpoint](https://fryerparts.pages.dev/api/search?q=00-411506-00013): plain GET, same matching as the MCP tool — `?q=` part number, spec string, Chinese keyword or a plain-language question ('can I use LCH instead of LC117'). Returns `matches` (part records) and `pages` (guides and comparisons). `&limit=` 1–20 - [MCP server](https://fryerparts.pages.dev/mcp): JSON-RPC 2.0 over HTTP; tools `search_parts`, `get_part`, `list_parts` - [MCP discovery](https://fryerparts.pages.dev/.well-known/mcp.json): transport, tool names, no auth - [WebMCP](https://fryerparts.pages.dev/webmcp.js): the same two read-only tools exposed in-page via `document.modelContext` for browser agents (progressive enhancement) - [Agent instructions](https://fryerparts.pages.dev/agents.md): what an assistant may and may not say about this site ## Dataset & citation - Version: 2026-11 (site release, last updated 2026-11-02) - Archived release: v2026-11 (2026-11-15). The DOI is the concept DOI, so it always resolves to the latest archived version — today that is this one. - Records: 16 part-number families - DOI: https://doi.org/10.5281/zenodo.23613053 - Repository: https://github.com/JSilent/fryer-parts-data - CSV mirror: https://huggingface.co/datasets/jsilent/fryer-parts-crossref - Cite as: Fryer Thermostat Parts Reference (2026). Commercial fryer parts number cross-reference dataset (v2026-11, 16 records; archived 2026-11-15). https://fryerparts.pages.dev/ · DOI 10.5281/zenodo.23613053 · CC0-1.0 ## Reuse Quote and cite freely under CC0 1.0. Attribute to "Fryer Thermostat Parts Reference" and link the specific page used. Do not describe this site as a supplier.