8500 W element assemblies for 50 lb electric fryers, supplied in three voltage-specific part numbers: 208 V (00-416741-000G9), 240 V (00-416741-00G11) and 480 V (00-416741-00G12). Used on Hobart HFD50 / HFC50 and Vulcan 1ER50 / ERC / ERD series; two elements per fryer.
Part numbers: 00-416741-000G9 / 00-416741-00G11 / 00-416741-00G12
| Family | 50 lb electric fryer element assembly |
|---|---|
| Wattage | 8500 W (8.5 kW) on all three voltage versions |
| Voltage variants | 208 V / 240 V / 480 V — three separate part numbers |
| Dimensions (208 V) | 9.4" x 21.75" x 6.75" |
| Dimensions (240 V) | 12.9" x 20.7" x 6.75" |
| Dimensions (480 V) | 8.75" x 20.4" x 6.7" |
| Phase / terminals | not published in the sources checked |
| Quantity per fryer | 2 |
These are the points that most often cause a wrong order on this specific part number. They are not generic advice.
Compiled from manufacturer catalog strings and distributor listings. Verify against your own equipment's parts manual before ordering. This is not an offer or a quotation.
These numbers are not reconstructed from distributor tables — each one is a line item in Vulcan-Hart's own replacement-parts catalogue. According to the Catalog of Replacement Parts — ER Series Fryer, FORM F-43220 Rev. A (April 2015), p. 18, the 240 V row reads “Element Assy. (240 V., 8500 kW) (50 Series)” and the 208 V row reads “Element Assy. (208 V., 8500 kW) (50 Series)”, with an AMT of 2 against each — two elements per fryer. The lines are reproduced below exactly as printed:
| Item | Part no. | Name of part (verbatim) | Amt |
|---|---|---|---|
| 11 | 00-416741-000G9 | Element Assy. (208 V., 8500 kW) (50 Series) | 2 |
| 13 | 00-416741-00G11 | Element Assy. (240 V., 8500 kW) (50 Series) | 2 |
| 12 | 00-416741-00G12 | Element Assy. (480 V., 8500 kW) (50 Series) | 2 |
| 2 | 00-422322-000G1 | Element Head Assy. (50 Series) | 1 |
Source: Vulcan-Hart Division of ITW Food Equipment Group, LLC, Catalog of Replacement Parts — ER Series Fryer, F-43220 Rev. A (April 2015), Heating Element Assembly, p. 18 (illustration PL-59481). Retrieved 2026-10-27: https://static-pt.com/modelManual/VH-ER_SERIES_pm.pdf. Quoted under fair use for identification; the manual is the publisher's document.
The same element family is supplied as separate part numbers per voltage. Pick the row that matches your fryer's data plate:
| Voltage | Part number | Notes |
|---|---|---|
| 208 V | 00-416741-000G9 | 9.4" x 21.75" x 6.75" |
| 240 V | 00-416741-00G11 | 12.9" x 20.7" x 6.75" |
| 480 V | 00-416741-00G12 | 8.75" x 20.4" x 6.7" |
00-416741-000G9416741-000G9416741-G900-416741-00G11416741-00G11416741-G1100-416741-00G12416741-00G128197531 (AllPoints, 240 V)An element is a resistive coil in a metal sheath: at its rated voltage it draws the rated current and converts it to heat. It fails open (no heat), shorts to the sheath (breaker trips, or the fryer becomes live), or degrades locally (slow recovery, hot spots, scorched oil). A wrong-voltage element does not fail at all — it just makes the wrong amount of heat, which is harder to notice: a 240 V element run at 208 V delivers about 75% of its rated wattage.
| Symptom | This part? | Check first |
|---|---|---|
| No heat at all, contactor pulls in | Yes — coil open | Continuity across the element terminals, then the contactor and hi-limit |
| Breaker or RCD trips when the element is switched on | Yes — short to sheath | Insulation resistance from terminal to earth; stop using the fryer |
| Slow recovery, oil will not hold temperature | Possible — partial failure or wrong voltage | Element resistance vs the table above; supply voltage at the element |
| One area of the oil scorches, rest is cool | Possible — local hot spot | Element sagging or touching the vat; scale on the sheath |
Cold resistance and current follow from the numbers on this page — R = V² ÷ W, I = W ÷ V. Use them as the comparison for a meter reading, not as a tolerance: resistance rises as the element heats.
| Supply | Rated power | Expected cold resistance | Expected current |
|---|---|---|---|
| 208 V | 8500 W | 5.1 Ω | 40.9 A |
| 240 V | 8500 W | 6.8 Ω | 35.4 A |
| 480 V | 8500 W | 27.1 Ω | 17.7 A |
The 208 V, 240 V and 480 V versions of this 8500 W assembly are three separate part numbers. Voltage is the first thing to confirm before ordering.
Hobart HFD50 / HFD50F / HFC50 / HFC50F and Vulcan 1ER50 / 2ER50 / ERC / ERD series 50 lb electric fryers. Two elements are used per fryer.
No aftermarket equivalent was found for the 8500 W assembly class in the sources checked.
Capillary, millivolt and high-limit thermostats in these part families are produced in volume in China. Public supplier directories list manufacturers concentrated in specific industrial clusters: Zhongshan (Guangdong) for capillary, millivolt and deep-fryer thermostats; Wenzhou (Zhejiang) for capillary, gas, immersion and mechanical thermostats with OEM/ODM capability; and Jinan (Shandong) for gas-valve and thermostatic gas-control components. When sourcing these parts from China, verify: dimensional drawings, sensing-bulb and capillary specifications, temperature accuracy, electrical ratings, cycle-life testing and applicable safety certifications (CE / CQC / UL). A high-limit safety thermostat must not be substituted on the basis of physical fit alone.
Compiled from OEM parts manuals and distributor catalogs. Part numbers, dimensions and electrical ratings are reproduced as published by these sources. Specifications marked "not published" were not available in the sources checked. Last compiled: 2026-10-31.